CyberPower Monitored PDU Series - PDU31001

Item # CYBPDU31001 (Part # PDU31001)
Not Available
Brand new, USA Warranty
and choose One-Day Shipping at checkout.
Item Description:
120V (8) 5-15R Out 5-15P 12ft Cord 1U 3YR Wty

The CyberPower PDU31001; an 8-outlet (front); 1U rackmount monitored power distribution unit (PDU) provides 120V 15A output. PDU31001 distributes power to 8 NEMA 5-15R receptacles from a single NEMA 5-15P plug with unfiltered electrical pass-through. Monitor power status over the network by using the CyberPower management console and the RJ45 Ethernet port for network connection. Monitor power status locally by using the LCD.

The PDU31001 comes with a three-year limited warranty that covers defects in materials and workmanship in the product under normal use and conditions.

Power Distribution

Delivers AC power to servers; equipment and connected devices via a power distribution unit.

Switch-Free Design

Safeguards against accidental power shut down.

Cyberpower Management Console

A hardware interface built into monitored and switched PDUs. It can perform tasks such as load monitoring and event logging.

Remote And Local Monitoring

Enables offsite and onsite tracking of PDU vitals; provides outlet control for individual and networked clients.

Automatic Event Notifications

Provides immediate updates about power events via email; SMS text; or SNMP traps

Upgradeable Firmware

Downloadable firmware updates to improve programs that run the PDU

Digital Display

Provides easy-to-read information about amperage; voltage; KW; IP address and other PDU information.

Network-Grade Plugs And Outlets

Highly durable construction ensures the efficient distribution of power to servers; equipment and connected devices in demanding IT or industrial environments

Long Input Power Cord

The PDU is able to be placed where it's needed because it reaches distant power sources.

Cord Retention Tray

Secures power cords; keeping them organized and accessible. Helps cords stay plugged in.

Mounting Brackets

Design allows PDU to be installed in a rack or horizontally or vertically; under a counter or via wall mount.

Durable Metal Housing

Protects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.

Three-Year Limited Warranty

Covers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date. See warranty for details.

Understanding Pdus

Power Distribution Units (PDUs) by CyberPower are engineered to distribute reliable network power to multiple devices. A PDU does not generate conditioned power; but delivers AC power from a UPS (uninterruptible power supply); a generator; or utility power source to servers; network/telecom equipment and other devices. Selecting the best PDU for your needs depends on the output voltage required; the number of outlets needed for connected devices; plug and outlet types and mounting options.

Versatile. CyberPower PDUs are designed with as many as 38 outlets. Offered in 0U; 1U and 2U form factors; each PDU includes the necessary hardware to be mounted vertically or horizontally inside densely configured rack enclosures. The PDU can also be mounted on a wall or under a shelf.

Scalable. In smaller networks; conditioned power can be distributed through a single PDU from a UPS; while a complex data center might require the connection of multiple PDUs to a large-capacity UPS system.

Different Pdu Series For Different Needs

CyberPower offers multiple offerings of power distribution units (PDUs): Basic; Metered; Metered ATS; Monitored; Switched; Switched ATS and Maintenance-Bypass. Each series serves a specialized purpose. Models within the same series have similar features and capabilities.

Basic: Reliable and unfiltered AC power distribution from a UPS system; generator and/or utility source to multiple connected devices.

Metered: Network-grade power distribution plus load meters (amps) to prevent overloads and safely optimize load levels.

Monitored: Network-grade power distribution with remote monitoring through an SNMP network interface and local management via a digital meter display to prevent downtime due to overloads or other power events.

Switched: Intelligent; network-grade power distribution and the ability to control outlets individually or collectively to solve power issues such as shutdowns or to plan scheduled rebooting. A digital meter provides information on load and voltage; as well as local control of the outlets. An SNMP connection enables remote monitoring and control of the outlets to ensure complete control regardless of location.

Switched Metered-by-Outlet: Monitor the power consumption of individual outlets in real-time over the network; or locally using the PDU's interactive digital display. Outlets can be switched on and off remotely for unscheduled reboots; automated load shedding; controlled power-cycling and more.

Metered ATS: Redundant NEMA plugs. Dual power cords can be plugged into separate power sources. If power for the primary source exceeds the lower or upper thresholds; or if power fails; the PDU will switch to the secondary power source to ensure continuous operation.

Switched ATS: Individual management of switched outlet receptacles. Remote and local control of outlets. Redundant NEMA plugs. Dual power cords can be plugged into separate power sources. If power for the primary source exceeds the lower or upper thresholds; or if power fails; the PDU will switch to the secondary power source to ensure continuous operation.

Maintenance-Bypass: Maintenance Bypass PDUs allow the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance; replacing batteries; or installing a new UPS.

Power Device Network Utility

The Power Device Network Utility gives users an easy-to-use interface for establishing the IP addresses of CyberPower PDU devices; RM Cards and Power Panel Business Edition Agents and Clients. It scans network devices with MAC addresses that match CyberPower network hardware. Once found; the device(s) can then be configured with a specific IP address; subnet mask and gateway address; allowing the device(s) to work properly on the network and to integrate with the CyberPower Management Console.

Cyberpower Management Console

The CyberPower Management Console is a Network Management System (NMS) that provides real-time remote power monitoring and control of Power Distribution Units (PDUs). This useful hardware interface is built into CyberPower Switched and Monitored PDUs. For both Switched and Monitored PDUs; the Management Console enables administrators to perform operational tasks; such as load monitoring and event logging via email; text; or SNMP trap notifications. With a Switched PDU; it enables manual power cycling to restart unresponsive devices and allows for scheduled power cycling of outlets and/or load shedding for specific devices connected to the PDU..

Specifications:

General

  • Type: Monitored
  • Phase: Single Phase

Input

  • Voltage: 100 - 120Vac
  • Frequency: 50Hz/60Hz
  • Maximum Input Current: 15A (Derated to 12A)
  • Plug Type: NEMA 5-15P
  • Plug Style: Straight
  • Cord Length (ft.): 12
  • Cord Length (m): 3.7

Output

  • Nominal Output Voltage: 100 - 120Vac
  • Overload Protection (Each Bank): None
  • Outlets - of Banks: 1
  • Outlets - Total: 8
  • Outlets - Front: 8
  • Outlets - Rear: 0
  • Outlet Type: NEMA 5-15R
  • Meter Readout: Power Control Display
  • LED Indicators: Tx/Rx; LINK; Normal/Warning/Critical Status

Management & Communications

  • Outlet switching: No
  • SNMP / HTTP Remote Monitoring: IPv4 TCP/IP UDP SNMPv1 HTTP NTP DNS Telnet DHCP SMTP FTP IPv6 SNMPv3 HTTPs SSH SSL TLS LDAP(S) RADIUS Syslog CLI Windows AD
  • Network Connection: RJ45 (Ethernet); RJ45 (COM Port)
  • Environmental Sensor: Optional; via RJ45
  • Updateable firmware: Yes; via USB or Ethernet
  • Multifunction LCD Screen: Voltage; Frequency; Load; Current; HW/FW Version; Network information

Physical

  • Standard Form Factor: 1U Rackmount
  • Form Factors Supported: Vertical or horizontal mounting supported in wall mount applications; racks and a variety of other surface types
  • Style: Horizontal Rackmount Wall mount
  • Enclosure Construction: Steel
  • Cord Retention Tray/Cord Organizers: Yes
  • External Site Ground Pin: Yes
  • Adjustable Mounting Brackets: 1 set

Physical Size

  • Dimensions (WxHxD): 17.05 x 1.75 x 4.41 in.
  • Weight: 5.3 lbs.
  • Installed Rack Height: 1U

Environmental

  • Operating Temperature: 32 degreeF - 131 degreeF (0 degreeC - 55 degreeC)
  • Operating Humidity: 0% - 95% non-condensing
  • Maximum Operating Elevation: 11480 ft (3;500 m)

Certifications

  • Safety: UL 60950-1
  • Environmental: RoHS Compliant

Warranty

  • Warranty: 3 Years
This Kit Includes: